Description
Case CX130, CX160, CX210, CX240 Service Training Manual
The reservoir is pressurized on all models. The air charge is provided by thermal expansion and the differential area of the cylinders as they are stroked the first time. There is a breather/pressure regulator/fill cap installed in the top cover of the units.
A rubber-covered button on top of the breather is provided to release the air pressure in the reservoir. A sight gauge mounted to the side of the reservoir indicates the oil level. There is a 150-mesh screen at the outlet of the reservoir to the hydraulic pump.
[pdf-embedder url=”https://excavatormanual.com/wp-content/uploads/2019/05/Case-CX130-CX160-CX210-CX240-Service-Training-Manual.pdf” title=”Case CX130, CX160, CX210, CX240 Service Training Manual”]
MODEL: CX130, CX160, CX210, CX240
Service Training Manual
Table of Contents
Section 1
General Introduction
Section 2
Component Locations – Hydraulics / Electrical
Section 3
Controller
Section 4
Electrical – “How it Works”
Section 5
Hydraulic – CX130/CX160 “How it Works”
Section 6
Hydraulic – CX210/CX240 “How it Works”
Section 7
Pressure Data
Section 8
Engine Electronic Fuel System
Section 9
Schematics